SF Series
IEEE-488.2/RS-232 Option
Programming Manual
Power Supplies
Elgar Electronics Corporation
9250 Brown Deer Road
San Diego, CA 92121-2294
1-800-73ELGAR (1-800-733-5427)
Tel: (858) 450-0085
Fax: (858) 458-0267
www.elgar.com
©2004 by Sorensen, Division of Elgar Electronics Corporation
This document contains information proprietary to Sorensen, Elgar Electronics Corporation. The information
contained herein is not to be duplicated or transferred in any manner without prior written permission from Sorensen.
November 5
,
2004 Document No. M550292-03 Rev 01
Zobrazit stránku 0
1 2 3 4 5 6 ... 47 48

Shrnutí obsahu

Strany 1 - SF Series

SF Series IEEE-488.2/RS-232 Option Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 921

Strany 2

Configuration Sorensen SF Series 2.2 Rear Panel Configuration Switch The DIP switch is accessible from the rear panel to allow configuration of the

Strany 3 - SAFETY NOTICE

Sorensen SF Series Configuration Powering up in remote mode will result in the following operating conditions: REMOTE MODE POWER-ON CONDITIONS Condi

Strany 4

Configuration Sorensen SF Series ADDRESS SWITCHES Switch Position Description ON 1 OFF 0 2.3 Remote Programming Via RS-232 The DIA’s RS-232 inte

Strany 5 - CONTENTS

SECTION 33.1 3.2 3.2.1 IEEE 488.2 AND SCPI COMMAND OPERATION Introduction The following sections describe the operation of the DIA by remote program

Strany 6 - SECTION 5

IEEE 488.2 and SCPI Command Operation Sorensen SF Series SCPI STATUS BYTE Bit Hex Value Description 0 0x01 Not used. 1 0x02 Protection Event Status

Strany 7 - AND SPECIFICATIONS

Sorensen SF Series IEEE 488.2 and SCPI Command Operation 3.2.3 Protection Condition and Protection Event Status Register These two registers have th

Strany 8 - 1.3 Specifications

IEEE 488.2 and SCPI Command Operation Sorensen SF Series SCPI ERROR CODES Error Code Description 206 No channels setup to trigger This means that

Strany 9 - CONFIGURATION

Sorensen SF Series IEEE 488.2 and SCPI Command Operation Error Code Description -200 Execution error An error/event number in the range [-299,-200]

Strany 10 - 2.2.1 Remote/Local Selection

IEEE 488.2 and SCPI Command Operation Sorensen SF Series 3.2.6 3.3 3.3.1 Serial Poll Operation Performing a serial poll will not modify the Status

Strany 11 - Address Selection

Sorensen SF Series IEEE 488.2 and SCPI Command Operation 3.3.2 Units The Series DIA will accept the following units as suffixes to numeric values:

Strany 13 - COMMAND OPERATION

IEEE 488.2 and SCPI Command Operation Sorensen SF Series 3.4 IEEE-488.2 Common Command Subsystem The following commands are common to all SCPI ins

Strany 14

Sorensen SF Series IEEE 488.2 and SCPI Command Operation Command Description SCPI *STB? Returns the integer value of the Status Byte with bit 6 re

Strany 15 - Error/Event Queue

IEEE 488.2 and SCPI Command Operation Sorensen SF Series 3.5.2 SOURCE SCPI Command Reference In the following table a "C" in the SCPI c

Strany 16

Sorensen SF Series IEEE 488.2 and SCPI Command Operation Command Description SCPI Q? :STATus :BLOCk? Returns the block of data critical

Strany 17

IEEE 488.2 and SCPI Command Operation Sorensen SF Series THE RAMP FUNCTION The ramp function allows the user to transition from one current to anot

Strany 18 - Parameter Definitions

Sorensen SF Series IEEE 488.2 and SCPI Command Operation 3.6.2 MEASURE SCPI Command Reference In the following table a "C" in the SCPI co

Strany 19 - 3.3.4 Queries

IEEE 488.2 and SCPI Command Operation Sorensen SF Series 3.7 3.7.1 3.7.2 OUTPUT SCPI Command Subsystem OUTPUT SCPI Command Summary OUTPut :PROTect

Strany 20

Sorensen SF Series IEEE 488.2 and SCPI Command Operation 3.8 3.8.1 3.8.2 STATUS SCPI Command Subsystem Note: See Section 5 for further information.

Strany 21 - SOURCE SCPI Command Summary

IEEE 488.2 and SCPI Command Operation Sorensen SF Series Command Description SCPI Q? :PROTection C :CONDition? Returns the integer value

Strany 22

Sorensen SF Series IEEE 488.2 and SCPI Command Operation 3.9 3.9.1 3.9.2 SYSTEM SCPI Command Subsystem SYSTEM SCPI Command Summary SYSTem :ERRor?

Strany 23

SAFETY NOTICE Before applying power to the system, verify that the SF Series supply is configured properly for the user’s particular application. WARN

Strany 24 - MEASURE SCPI Command Summary

IEEE 488.2 and SCPI Command Operation Sorensen SF Series Command Description SCPI Q? SYST:LOCAL SYST:LOCAL <ON|OFF> is a special purpose prog

Strany 25

Sorensen SF Series IEEE 488.2 and SCPI Command Operation 3.10 3.10.1 3.10.2 TRIGGER SCPI Command Subsystem TRIGGER SCPI Command Summary TRIGger :AB

Strany 26 - OUTPUT SCPI Command Summary

IEEE 488.2 and SCPI Command Operation Sorensen SF Series 3.11.1 CALIBRATION SCPI Command Summary CALibrate :DATA <NRf><NRf><NRf>

Strany 27 - STATUS SCPI Command Summary

Sorensen SF Series IEEE 488.2 and SCPI Command Operation 3.11.2 CALIBRATION SCPI Command Reference In the following table a "C" in the SC

Strany 28

IEEE 488.2 and SCPI Command Operation Sorensen SF Series Command Description SCPI Q? :POINt <1|2> <NRf> Sets the voltage measu

Strany 29 - SYSTEM SCPI Command Summary

Sorensen SF Series IEEE 488.2 and SCPI Command Operation // turn on with no load at the output. *CLS // clear the unit to its power-on defa

Strany 30

IEEE 488.2 and SCPI Command Operation Sorensen SF Series This page intentionally left blank. 3-24 M550292-03 (Programming)

Strany 31 - TRIGGER SCPI Command Summary

SECTION 4 CALIBRATION WARNING Please refer to the power supply manual for further information before performing calibration procedures. Calibration

Strany 32

SCPI STATUS IMPLEMENTATION Sorensen SF Series 3. Connect the power supply for sensing at the required load point. Refer to the power supply manual

Strany 33

Sorensen SF Series IEEE 488.2 and SCPI Command Operation 6. Program the output of the second calibration point to approximately 85% of full scale v

Strany 34

SAFETY SYMBOLS

Strany 35

SCPI STATUS IMPLEMENTATION Sorensen SF Series 4. Let the output settle and measure the current with the current shunt and the meter. 5. Enter the

Strany 36

Sorensen SF Series IEEE 488.2 and SCPI Command Operation 4. Let the output settle and measure the current with the current shunt and the meter. 5.

Strany 37 - CALIBRATION

SCPI STATUS IMPLEMENTATION Sorensen SF Series 4. Let the output settle and measure the current with the current shunt and the meter. 5. Enter the

Strany 38

SECTION 5 SCPI STATUS IMPLEMENTATION M550292-03 (Programming) 5-1

Strany 39

SCPI STATUS IMPLEMENTATION Sorensen SF Series This page intentionally left blank. 5-2 M550292-03 (Programming)

Strany 40

Various fault events must be enabled by the protection enable register before they are recorded in the fault register. Bit Hex Value Descripti

Strany 42

INDEXC CALibrate, 3-20 Calibration, 4-1 Current Measurement/Readback Calibration, 4-4 Current Programming and Readback Calibration, 4-5 Current Prog

Strany 43 - SCPI STATUS IMPLEMENTATION

Index Sorensen SF Series M MEASURE SCPI Command Reference, 3-13 MEASURE SCPI Command Subsystem, 3-12 O Operation Status and Questionable Status Regi

Strany 44

CONTENTS SECTION 1 FEATURES, FUNCTIONS, AND SPECIFICATIONS ...1-1 1.1 Introduction...

Strany 45

Contents Sorensen SF Series 3.5.1 SOURCE SCPI Command Summary...3-9 3.5.2 SOURCE SCPI Command Refer

Strany 46

SECTION 11.1 Introduction 1.2 FEATURES, FUNCTIONS, AND SPECIFICATIONS This manual covers the Digital Interface Adapter (DIA) for SF Series supplies

Strany 47

Features, Functions, and Specifications Sorensen SF Series 1-2 M550292-03 (Programming) Readback Functions • Actual measured voltage and cur

Strany 48

SECTION 22.1 CONFIGURATION The DIA is installed into the supply at the factory. Use the Setup Procedure described below to configure the DIA for yo