M362250-01 Rev C www.programmablepower.com
DCS-E 1kW Series,
DLM-E 3kW & 4kW
Power Supplies
M51A Option: Isolated Analog
Programming Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - DLM-E 3kW & 4kW

M362250-01 Rev C www.programmablepower.com DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual

Strany 2

Contents DLM-E Series and DCS-E Series LIST OF TABLES Table 2–1. SW1 SETUP Switch...

Strany 3

SECTION 1 M51A OPTION OVERVIEW 1.1 Introduction This manual is to be used in conjunction with the DCS-E 1kW Series & DCS-E 1.2kW Series DC Power

Strany 4

M51A Option Overview DLM-E Series and DCS-E Series 1-2 M51A Option 1.3 Specifications 1.3.1 Electrical Specifications Remote Voltage Programming A

Strany 5 - Programming Manual

SECTION 2 ISOLATED ANALOG PROGRAMMER OPERATION 2.1 SW1 Switch The SW1 SETUP switch is accessible from the rear panel of the unit. It provides user

Strany 6

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.1.1 SW1 Switch Setup The following sections describe the functions of the vari

Strany 7 - SAFETY SYMBOLS

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.2 ISOLATED ANALOG PROGRAMMER Connector (J4) The ISOLATED ANALOG PROGRAMMER co

Strany 8

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2-4 M51A Option 2.2.1 ISOLATED ANALOG PROGRAMMER Functions The following secti

Strany 9 - CONTENTS

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation M51A Option 2-5 Analog Programming Signals OVP PROGRAMMING INPUT: Pin-3, an i

Strany 10

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2-6 M51A Option Auxiliary Sources AUXILIARY DC OUTPUT: Pin-15, 16VDC source for

Strany 11 - M51A OPTION OVERVIEW

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3 Remote Programming Configuration 2.3.1 Voltage Source Programming of Outpu

Strany 13 - PROGRAMMER OPERATION

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.2 Voltage Source Programming of Output Current SW1 Switch Settings SW1-2 ON

Strany 14 - 2.1.1 SW1 Switch Setup

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.3 Voltage Source Programming of OVP SW1 Switch Settings SW1-3 ON (1) = 0–5

Strany 15 - 12 Isolated Analog Common

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.4 Resistance Programming of Output Voltage SW1 Switch Settings SW1-1 ON (1)

Strany 16

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.5 Resistance Programming of Output Current SW1 Switch Settings SW1-2 ON (1

Strany 17

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.6 Resistance Programming of OVP SW1 Switch Settings SW1-3 ON (1) = 0–5K 23

Strany 18

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.7 4-20mA Current Source Programming of Output Voltage SW1 Switch Settings

Strany 19 - 291213 1

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.8 4-20mA Current Source Programming of Output Current SW1 Switch Settings S

Strany 20 - 2101213 1

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 2.3.9 Programming the Shutdown Function 21312515+5VGND14 Figure 2–3. Using Shu

Strany 21 - 2361213 1

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.11 Shutdown Application – Contact Closure An external relay, whether normally

Strany 22

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation 13 125 1514 Figure 2–5. Using Shutdown with Contact Closure of a Normally OPEN

Strany 24

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2.3.12 Local/Remote Application An external relay or switch may be used to select

Strany 25 - 91213 12

DLM-E Series and DCS-E Series Isolated Analog Programmer Operation M51A Option 2-19 2.4 Remote Monitoring Analog signals are available for monitor

Strany 26 - 111213 12

Isolated Analog Programmer Operation DLM-E Series and DCS-E Series 2-20 M51A Option This page intentionally left blank.

Strany 28

About AMETEK AMETEK Programmable Power, Inc., a Division of AMETEK, Inc., is a global leader in the design and manufacture of precision, programmable

Strany 29

This page intentionally left blank. ii

Strany 30

Important Safety Instructions Before applying power to the system, verify that your product is configured properly for your particular application.

Strany 31 - 2.4 Remote Monitoring

This page intentionally left blank. iv

Strany 32 - 2-20 M51A Option

CONTENTS SECTION 1 M51A OPTION OVERVIEW ............1-1 1.1 Introduction ...........