Programming Manual Lx \ Ls Series II
210
MS704:NORMal:VOLTage:TRANsient:UNDer
This command will run the steady state under voltage transients test.
Command Syntax MS704:NORMal:VOLTage:TRANsient:UNDer
Parameters none
Examples MS704:NORM:VOLT:TRAN:UND
Query Syntax none
MS704:NORMal:VOLTage:TRANsient:COMBination
This command will run the steady state combination voltage transients test.
Command Syntax MS704:NORMal:VOLTage:TRANsient:COMBination
Parameters none
Examples MS704:NORM:VOLT:TRAN:COMB
Query Syntax none
MS704:NORMal:VOLTage:TRANsient:REPetitve
This command will run the steady state repetitive voltage transients test.
Command Syntax MS704:NORMal:VOLTage:TRANsient:REPetitive
Parameters none
Examples MS704:NORM:VOLT:TRAN:REP
Query Syntax none
MS704:NORMal:FREQuency:MODulation
This command will run the steady state frequency modulation test.
Command Syntax MS704:NORMal:FREQuency:MODulation
Parameters none
Examples MS704:NORM:FREQ:MOD
Query Syntax none
MS704:NORMal:FREQuency:TRANsient[:ALL]
This command will run all the steady state frequency transients tests.
Command Syntax MS704:NORMal:FREQuency:TRANsient[:ALL]
Parameters none
Examples MS704:NORM:FREQ:TRAN
Query Syntax none