4.4 Diagnostic Subsystem
These subsystem commands perform diagnostic functions which include reading and writing to
the EEPROM, resetting the AC source and reading temperature.
Subsystem Syntax
DIAGnostic
:RESet Force power-on reset
:TEMPerature
:AMBient? Returns ambient temperature in °C
DIAGnostic:RESet
This commands forces a power-on reset.
Command Syntax DIAGnostic:RESet
Parameters None
Examples DIAG:RES
Related Commands *RST
DIAGnostic:TEMPerature:AMBient?
This query returns the temperature measured at the ambient sense thermistor in degrees C.
Query Syntax DIAGnostic:TEMPerature:AMBient?
Parameters None
Examples DIAG:TEMP:AMB?
Returned Parameters <NR3>