Ametek SFA Series Ethernet Programming Uživatelský manuál Strana 61

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 159
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 60
SG Series Programming Ethernet Configuration and Remote Programming
M550129-03 Rev K
5-21
5.5.3
SETTINGS
The Settings page is available to users who have FULL, Read/Write or Read
Only access to at least one power supply (Read Only users can make no
changes to the settings). In this page you will see continuous updates (2-5
times per second) of the actual voltage output (value displayed on the left)
and the actual live current output (value displayed to the right).
Figure 5-14. Settings Page
Voltage: value above is updated with actual voltage output of the power
supply
Current: value above is updated with actual live current output
Set V: the programmed voltage setting
Set I: the programmed current setting
Set OVP: the programmed over voltage protection setting
APPLY: puts into effect the newly input settings
CC and CV indicators: presently operating output mode of the power
supply, either constant voltage or constant current.
OVP indicator: highlighted red if over voltage protection is activated
Zobrazit stránku 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 158 159

Komentáře k této Příručce

Žádné komentáře