4.23 Status Subsystem Commands
This subsystem programs the AC/DC power source status registers. There are four groups
of status registers;
Operation Status Group
Questionable Status Group
Questionable Instrument Isummary Group
Standard Event Group
The Standard Event group is programmed with Common commands. The Operation,
Questionable, and Instrument ISummary status groups each consist of the following three
registers:
Condition Enable Event
Refer to chapter 7 for more information about the status registers.
Subsystem Syntax
STATus
:OPERation
:EVENt Returns the value of the event register
:CONDition Returns the value of the condition register
:ENABle <n> Enables specific bits in the Event register
:QUEStionable
:EVENt Returns the value of the event register
:CONDition Returns the value of the condition register
:ENABle <n> Enables specific bits in the Event register
:INSTruments
:ISUMmary
:EVENt Returns the selected phase’s event register value
:CONDition Returns the selected phase’s condition register
:ENABle Enable specific bits in selected phase’s Event
register values
Bit Configuration of Status Operation Registers
Bit Position 15-5 4 3 1-2 0
Bit Name not used MEAS TRANS not used CAL
Bit Weight 16 8 1
CAL Calibration is completed
TRANS Transient is completed
MEAS Measurement is completed