Ametek BPS Series Programming Manual Uživatelský manuál Strana 138

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 226
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 137
AMETEK Programmable Power BPS / MX / RS Series SCPI Programming Manual
138 Manual P/N 7003-961 Rev AA
5.10 *SAV
This command stores the present state of the AC/DC power source to a specified location in
memory. Up to 8 states (including the transient list) can be stored in nonvolatile memory.
Command Syntax *SAV
Parameters 0 through 7
Related Commands PSC *RCL *RST
5.11 *SRE
This command sets the condition of the Service Request Enable Register. This register
determines which bits from the Status Byte Register (see *STB for its bit configuration) are
allowed to set the Master Status Summary (MSS) bit and the Request for Service (RQS)
summary bit. A 1 in any Service Request Enable Register bit position enables the
corresponding Status Byte Register bit and all such enabled bits then are logically ORed to
cause Bit 6 of the Status Byte Register to be set. See paragraph 7.5 for more details
concerning this process.
When the IEEE-488 BUS controller conducts a serial poll in response to SRQ, the RQS bit is
cleared, but the MSS bit is not. When *SRE is cleared (by programming it with 0), the source
cannot generate an SRQ to the controller.
Command Syntax *SRE <NRf>
Parameters 0 to 255
Default Value 0 (see *PSC command)
Example *SRE 255
Query Syntax *SRE?
Returned Paramters <NR1>(Register binary value)
Related Commands *ESE *ESR
Zobrazit stránku 137
1 2 ... 133 134 135 136 137 138 139 140 141 142 143 ... 225 226

Komentáře k této Příručce

Žádné komentáře