BPS / MX / RS Series SCPI Programming Manual AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA 73
4.11 Output Subsystem
This subsystem controls the main outputs, the signal outputs and the output impedance [-3Pi
models only] of the AC/DC source.
Subsystem Syntax
OUTPut
[:STATe] <bool> Enable/disable output voltage, current, power, etc.
:IMMediate <bool> Open relay without programming down first
:PROTection
:CLEar Reset latched protection
:RI
[:LEVel] LOW | HIGH Sets Remote Inhibit input level mode.
:MODE <mode> set remote inhibit input (LATC|LIVE|OFF)
:TTLTrg
:MODE TRIG | FSTR Sets or disabled Function strobe mode.
[:STATe] <bool> Enable/disable trigger out drive
:SOURce <source> Selects a TTLTrg source (BOT|EOT|LIST)
:IMPedance
[:STATe] <bool> Enable/disable output impedance program
:REAL Sets resistive part of output impedance
:REACtive Sets inductive part of output impedance
4.11.1
Output Relay
OUTPut[:STATe]
This command enables or disables the source output. The state of a disabled output is an
output voltage amplitude set to 0 volts, with output relays opened. The query form returns
the output state.
Note: On three phase MX/RS/BPS systems with firmware revision below 0.31, it is
recommended to set the phase coupling to ALL before closing the output relay to ensure all
phases are correctly programmed. E.g. “inst:coup all:;outp 1”.
Command Syntax OUTPut[:STATe]<bool>
Parameters 0 | OFF | 1 | ON
*RST Value OFF
Examples OUTP 1 OUTP:STAT ON
Query Syntax OUTPut[:STATe]?
Returned Parameters 0 | 1
Related Commands VOLT:RANGE